E-BOX MODULAR, emergency stop contact module, 250 V, 2 NC
Article number: 5.00.100.227/0100
Technical data
|
General |
|
| Operating temperature, min. | -25 °C |
| Operating temperature, max. | 70 °C |
| Storage temperature, min. | -40 °C |
| Storage temperature, max. | 80 °C |
| illuminated | No |
| Packaging | Box |
| Packaging unit | 1 pcs. |
| Net weight | 7.7 g |
| Operating life electrical |
1,000,000 (1A / 250V AC) cycles
100,000 (2A / 250V AC) cycles 30,000 (4A / 250V AC) cycles |
| B10 electrical |
1.300.000 (1A / 250V AC) cycles
200.000 (2A / 250V AC) cycles 70.000 (4A / 250V AC) cycles |
| B10d | 140,000 cycles |
| Protection class | II |
| Minimum order quantity (MOQ) | 5 pcs. |
| RoHS compliant | Yes |
| REACH compliant | Yes |
| Country of origin | DE |
|
Mounting dimensions |
|
| Outside dimension, length | 45 mm |
| Outside dimension, width | 32 mm |
| Outside dimension, height | 17.4 mm |
|
Mechanical characteristics |
|
| Fixing | Assembly clip |
| Contact function | 2 NC |
| Contact system | Bridge contact |
| Contact material | Silver |
| PIN 1 | Normally closed contact 1 |
| PIN 2 | Normally closed contact 1 |
| PIN 3 | Normally closed contact 2 |
| PIN 4 | Normally closed contact 2 |
|
Electrical characteristics |
|
| Rated voltage, min. | 10 V |
| Rated voltage, max. | 250 V |
| Voltage type | AC / DC |
| Rated operating voltage | 10-250 V |
| Operating current, min. | 1 mA |
| Rated current, min. |
|
| Power loss | 0.96000 W |
Drawings
Description
The elegant and flat E-BOX is the complete housing for RAFIX 22 FS+ control units. It is used where individual control devices are required at remote locations - for example, emergency stop applications along a production facility or at a safety fence. The compact dimensions of the E-BOX are based on the edge dimensions of a 40 mm profile rail. Installation is also designed with this in mind. This is quick and easy thanks to the modular system consisting of a lower and upper housing section, contact module with switching element and actuator.
The wiring of the terminals must be carried out by trained specialist personnel.