RAFIX 16, emergency stop, square collar, reset by rotating, Mushroom head red
Article number: 1.30.074.501/0304
Technical data
General |
|
Color of mushroom | red |
Collar color | black |
Collar shape | square |
Operating temperature, min. | -25 °C |
Operating temperature, max. | 70 °C |
Storage temperature, min. | -40 °C |
Storage temperature, max. | 85 °C |
illuminated | Yes |
Packaging | Box |
Packaging unit | 2 pcs. |
net weight | 9.1 g |
Operating life | 30,000 cycles |
B10 | 39,000 cycles |
B10d | 78,000 cycles |
Degree of protection, front side, according to DIN EN 60529 | IP65 |
Environment resistance |
IEC 60068-2-14
IEC 60068-2-30 IEC 60068-2-33 IEC 60068-2-78 |
MOQ order | 10 pcs. |
RoHS compliant | Yes |
REACH compliant | Yes |
Mounting dimensions |
|
Outside dimension, length | 24.95 mm |
Outside dimension, width | 24.95 mm |
Outside dimension, height | 37.9 mm |
Mounting hole | 16.2 mm |
Mounting depth | 44.7 mm |
Collar dimension | 24,95 x 24,95 mm |
Mechanical characteristics |
|
Actuation function | latching |
Resetting | by rotating |
Fixing | Threaded ring |
Threaded ring torque, max. | 1.2 Nm |
Drawings
Description
RAFIX control devices are modular units consisting of several parts. In the RAFIX 16 family, they always consist of an actuating element and a switching element, or of an indicator lamp and a lamp socket. Actuating elements (such as pushbuttons or emergency stop actuators) have the specified tactility, reset and function only when assembled with the appropriate switching elements. For illuminated actuators, please use switching elements with lamp socket.
The mounting diameter is 16.2 mm according to the standard. The anti-rotation lug can be easily removed with a screwdriver if necessary.
Main areas of application
- Measurement-control-regulation
- Electrical engineering
- Mechanical and system engineering
- Industrial robots
Special features
- Emergency stop for safety functions
- Override-proof in accordance with DIN EN ISO 13850 due to positively driven mechanical motion sequence
- Robust - also suitable for operation with gloves
- Close mounting of actuators possible, as wiring is axial from behind
- Degree of protection: IP 65 at the front
- Mounting diameter 16.2 mm
- Separate switching elements UNIVERSAL required
- Switching elements with silver contacts (max. 250 V / 6 A) or gold contacts (max. 35 V / 0.25 A)
- Connection types switching elements: screw connection, plug-in connection, PCB plug-in socket
- The switching elements are snapped on and can be removed again by turning.