RAFIX 16, universal switching element, gold, without lamp socket, quick-connect terminal, momentary contact function, 1 NC
Article number: 1.20.123.032/0000

Technical data
General |
|
Color | light gray |
Operating temperature, min. | -25 °C |
Operating temperature, max. | 70 °C |
Storage temperature, min. | -40 °C |
Storage temperature, max. | 85 °C |
illuminated | No |
Packaging unit | 20 pcs. |
net weight | 9.1 g |
Operating life | 2,000,000 cycles |
B10 | 2,600,000 cycles |
Environment resistance |
IEC 60068-2-14
IEC 60068-2-30 IEC 60068-2-33 IEC 60068-2-78 |
Shock resistance according to standard IEC 60068-2-27 | 50 g at 11 ms amplitude semi-sinusoidal |
Vibration resistance according to standard IEC 60068-2-6 | 10 g at 20 - 500 Hz |
Protection class | II |
MOQ order | 20 pcs. |
RoHS compliant | Yes |
REACH compliant | Yes |
Mounting dimensions |
|
Outside dimension, length | 22.2 mm |
Outside dimension, width | 22.2 mm |
Outside dimension, height | 34.4 mm |
Mounting depth | 44.7 mm |
Mechanical characteristics |
|
Actuation function | momentary contact function |
Operating force, max. | 100 N |
Operating travel, max. | 3 mm |
Contact function | 1 NC |
Contact system | Bridge contact |
Contact material | Gold |
Fixing | Latching |
Solderability | No |
Terminal on the rear | Flat quick-connect terminal 2.8 x 0.8 |
Electrical characteristics |
|
Rated voltage, min. |
|
Rated voltage, max. | 35 V |
Voltage type | AC / DC |
Rated operating voltage | 0.02-35 V |
Rated current, min. |
|
Rated current, max. |
|
Power loss | 0.000625 W |
Drawings
Description
RAFIX universal switching elements are designed for emergency stops and actuators with two actuating directions (e.g. selector switches). The universal switching elements always have a momentary contact function - then a switching function is implemented by the actuator alone.
Acceptance conditions according to UL certificate:
RAFIX control devices are defined at RAFI as modular elements, consisting of an actuating element, if necessary a coupling and an individual contact or lighting unit.
Actuating elements (such as pushbuttons, emergency stop actuators, etc.) have the intended tactility, reset and function only when assembled with the appropriate switching elements.