RAFIX 16, universal switching element, silver, without lamp socket, quick-connect terminal, momentary contact function, 1 NC
Article number: 1.20.123.022/0000
Technical data
General |
|
Color | light gray |
Operating temperature, min. | -25 °C |
Operating temperature, max. | 70 °C |
Storage temperature, min. | -40 °C |
Storage temperature, max. | 85 °C |
illuminated | No |
Packaging unit | 20 pcs. |
net weight | 7 g |
Operating life | 1,000,000 cycles |
B10 | 1,300,000 cycles |
Environment resistance |
IEC 60068-2-14
IEC 60068-2-30 IEC 60068-2-33 IEC 60068-2-78 |
Shock resistance according to standard IEC 60068-2-27 | 50 g at 11 ms amplitude semi-sinusoidal |
Vibration resistance according to standard IEC 60068-2-6 | 10 g at 20 - 500 Hz |
Protection class | II |
MOQ order | 20 pcs. |
RoHS compliant | Yes |
REACH compliant | Yes |
Mounting dimensions |
|
Outside dimension, length | 22.2 mm |
Outside dimension, width | 22.2 mm |
Outside dimension, height | 34.4 mm |
Mounting depth | 44.7 mm |
Mechanical characteristics |
|
Actuation function | momentary contact function |
Operating force, max. | 100 N |
Operating travel, max. | 3 mm |
Contact function | 1 NC |
Contact system | Bridge contact |
Contact material | Silver |
Fixing | Latching |
Solderability | No |
Terminal on the rear | Flat quick-connect terminal 2.8 x 0.8 |
Electrical characteristics |
|
Rated insulation voltage | 250 V |
Rated surge voltage | 2,500 V |
Rated operating voltage |
250 V (AC-15)
250 V / 125 V / 60 V / 24 V (DC-13) |
Rated voltage, min. | 10 V |
Rated voltage, max. | 250 V |
Voltage type | AC / DC |
Rated operating current I, AC15 B300 | 240 V / 1,5 A |
Rated operating current I, DC13 Q300 |
250 V / 0,275 A
125 V / 0,4 A 60 V / 1 A 24 V / 2 A |
Rated operating voltage | 10-250 V |
Power loss | 0.72000 W |
Category of use AC-15 / B300 | 250 V / 1,5 A (CCC) |
Categories of use |
AC-15 / B300
DC-13 / Q300 |
Category of use DC-13 / Q300 | 240 V / 0,27 A (CCC) |
Drawings
Description
RAFIX universal switching elements are designed for emergency stops and actuators with two actuating directions (e.g. selector switches). The universal switching elements always have a momentary contact function - then a switching function is implemented by the actuator alone.
Main areas of application
- Measurement-control-regulation
- Electrical engineering
- Mechanical and system engineering
- Industrial robots
Special features
- Suitable for emergency stop and actuators with 2 switching directions, such as selector switches and key switches
- Safe switching due to oxidation-free gold contacts (max. 35 V / 0.25 A)
- NC contacts forcibly separated according to IEC 60947-5-1
- Two separate switching chambers, so two different potentials can be switched
- Contact function momentary (switching functions are realized via the actuating element)
- Mounting by snapping onto actuator
- Disassembly by turning and pulling off
- Flat plug-in connections 2.8 x 0.8 mm (also with PCB plug-in base) or screw connection